this is just a test - Page 012

Jump to Page:

A
16:14
ARC tester
In reply to this message
Hi, please send this EEPROM dump and a photo of the stickers on the board here
JT
16:47
Jeannot Tremblay
In reply to this message
16:48
S19Jpro_100T_BHB42631_2.bin
not-archived
256 B
2022-September-13
A
01:37
ARC tester
In reply to this message
What type of chips are on the board?
JT
07:26
Jeannot Tremblay
In reply to this message
BM1362AK and with 2 solder air gun I'm not able to remove chip.

I'm put hashboard in reflow oven until 280 and I have tried to remove chip when card is in reflow. Nothing even condensator don't remove. This hashboard build very strong great job.
07:26
In reply to this message
07:40
In reply to this message
ARC don't show number of chips but it works for test. I see all my signals CLOCK RX RST LDOS.
A
07:57
ARC tester
In reply to this message
one minutes please
JT
08:03
Jeannot Tremblay
126
A
08:13
ARC tester
In reply to this message
we will now contact you in private messages, transfer you to the debug, within a couple of hours we will make a special firmware that will give us the answers of your board and we will add support for your board.
JD
08:14
Joe D.S. JTS
Screen Shot 2022-09-13 at 19.10.44.png
not-archived
153.2 KB
08:14
how to dump the eeprom information, the log file not show the hex information.
08:15
S19 J Pro. Hashboard BHB42631
08:15
A
08:21
ARC tester
In reply to this message
you can save the dump in EEPROM editor
JD
08:25
Joe D.S. JTS
Screen Shot 2022-09-13 at 19.24.17.png
not-archived
322.8 KB
08:25
Screen Shot 2022-09-13 at 19.24.24.png
not-archived
124.0 KB
08:32
In reply to this message
I think we're having the same problem.
08:33
In reply to this message
I use this dump file to flash on our hashboard and it work.
08:33
Screen Shot 2022-09-13 at 19.32.49.png
not-archived
587.1 KB
08:33
but still got "0 chip found"
A
09:06
ARC tester
In reply to this message
tell me the chip model and dump your board here
JD
09:12
Joe D.S. JTS
09:12
BM1362AK
09:13
In reply to this message
I cannot dump the board. It show empty
09:13
In the miner log file also no information.
09:14
A
09:33
ARC tester
We are preparing a solution to your question. When we are ready, we will contact you in private messages.
KH
09:38
Kylie Jo Hamilton
In reply to this message
The tester was missing the fuse entirely. I tried to put one on from another tester but it’s still stuck in PIC error
A
09:39
ARC tester
What with 3.3?
KH
09:39
Kylie Jo Hamilton
F2 fuse
A
09:39
ARC tester
In reply to this message
👆🏼
KH
09:40
Kylie Jo Hamilton
It was missing entirely so I used an F2 fuse from a previous tester and no it doesn’t get 3.3 volts
A
09:41
ARC tester
What with 5volts at the entrance ?
09:42
09:42
Check it please
JD
09:42
Joe D.S. JTS
In reply to this message
Thank you
R
11:07
Rust Project
11:08
Hi. I have this error on 2 t17 hb
11:08
The boards seems ok on tester ... any help?
11:09
Error_temperature_too_high
11:09
KH
11:22
Kylie Jo Hamilton
In reply to this message
Yes I have 4.9 Vs
11:22
A
11:26
ARC tester
In reply to this message
Tell to your boss to write me by email please. Thank you
Taylor invited Deleted Account
C
16:19
Cody
Anyone have an S19 Pro (110T) dump?
J
17:33
Jasa
Hello everyone... I have a problem with a hashboard T17... the voltages and signal it's ok, and the test normal look perfect, but in advance test the hashboard fail... why?
17:33
Video file
not-archived
00:13, 5.9 MB
17:35
In reply to this message
Note: the power supply VDD IN = 17.6 V ... the voltage in hashboard test is less in screen
R
20:59
Raz
In reply to this message
Hey Jasa
What is your PSU?
21:00
Put your voltage at 21v, amp to max, while doing your tests

Then, if you got red at Advanced test (little thunder), you could check BI signal, it's supposed to be at 0
21:04
while advanced test on, check all the chips from last to first. If you got a chip that has a Bi of 1.8, usually it's that one that is causing the problem
21:08
But yeah, red advanced test on T17 is not an easy one
J
21:08
Jasa
Hi Raz, the Power supply is 30V / 10Amp max... I'll try again testing signals in hashboard...
21:10
In 3rd domain voltage is equal to 2.3v, when normally is 1.5 to 1.9v in the other domains
R
21:11
Raz
In reply to this message
So you got 1 domain that LDO 2.3 instead of 1.8?
J
21:20
Jasa
That fail was fixed in another domain...
2022-September-14
P
02:25
P
02:26
Pls help i want dump file of this version s19j pro 104t
2022-September-15
A
05:53
ARC tester
Hello! Today is last chance to upgrade your ARC to full version with 500$ price.
ARC tester pinned this message
MA
06:03
Meshal Adel
In reply to this message
How can I know if my ARC is pro ?
A
06:04
ARC tester
In reply to this message
Write me please serial number of your arc
MA
06:10
Meshal Adel
Sure
R
12:08
Rust Project
hi! On a t17, where is the problem?
12:08
2022-09-15 16:07:53 temperature.c:697:get_temp_info: read temp sensor failed: chain = 0, sensor = 3, chip = 184, reg = 1
2022-09-15 16:07:54 thread.c:734:check_temperature: over max temp, pcb temp 61 (max 80), chip temp 191(max 103)
2022-09-15 16:07:54 driver-btm-api.c:205:set_miner_status: ERROR_TEMP_TOO_HIGH
CW
12:54
C W
Hi guys I hope that everything is great ! I have a question about s19 al (88 chips) I could find 45 chips with the tester, but when I tried to inject 1.2 v to the RO of the 1st chip I got 0 ASICS 😓 could anyone tell me which part I did wrong ? Thank you so much !!
12:56
-
12:57
Like that with a shorting probe 😓
R
13:33
Radu/nERD
In reply to this message
I think on chain 0 chip 3 has a bad temp lecture of 191. Max temp is 103
R
14:00
Rust Project
how can i reed this: read temp sensor failed: chain = 0, sensor = 3, chip = 184, reg = 1
14:01
what means chip=184?
DG
14:57
Dariusz G
Today WM ARC was saying "Unknown Answers" as a result. Any information about this error? M31S board
A
15:13
ARC tester
In reply to this message
this is garbage, distortion of signals by chips/board, the tester notifies you about this problem
R
15:21
Rust Project
anyone with t17 experience? AR tester detect 30 chips, sensor are ok but still get this error:
15:21
2022-09-15 19:19:08 thread.c:734:check_temperature: over max temp, pcb temp 50 (max 80), chip temp 104(max 103)
2022-09-15 19:19:08 driver-btm-api.c:205:set_miner_status: ERROR_TEMP_TOO_HIGH
2022-09-15 19:19:08 driver-btm-api.c:146:stop_mining: stop mining: over max temp
2022-09-15 19:19:08 thread.c:920:cancel_temperature_monitor_thread: cancel thread
2022-09-15 19:19:08 thread.c:930:cancel_read_nonce_reg_thread: cancel thread
2022-09-15 19:19:08 driver-btm-api.c:131:killall_hashboard: ****power off hashboard****
15:21
its drive me crazy :)
CW
15:30
C W
In reply to this message
Hi there, you could try to replace all 4 of the sensors and see if the problem still persists 😓 if you have the parts readily available. Do you have any s19 88 experience ?😅
R
15:30
Rust Project
nooop, only s9 ... its first t17 ...
J
15:31
Jasa
In reply to this message
Where is your log?? I has a similar problem... just u need to know if the problem is sensors or asic..
R
15:31
Rust Project
eroare temperatura t17.txt
not-archived
4.6 KB
error
15:32
seems like asic, but on tester all sensors are detected and are ok
CW
15:32
C W
In reply to this message
Ok thanks none the less, if you did replace all the sensors and the problem is still there, then you could deduce the problem to other things on the board 👍
15:33
In reply to this message
Sorry if I was stating the obvious but I hope it helps....
J
15:33
Jasa
In reply to this message
RI signal injection, goes from the last asic to the first... the signal is normally High
CW
15:35
C W
In reply to this message
Yes that was exactly what I was trying to do, but when I did it like the picture I sent, the asic count on the tester sudden dropped to 0, and all voltages were screwed up😓😓 like CI clk etc. I know it should be 1.2v right now I don’t have that😓😓
J
16:14
Jasa
In reply to this message
😨 what the heck..?? The voltages in regulators and domains is OK?

maybe some asic failed completely..
16:18
In reply to this message
The 4-sensor temp is Ok... (pcb-trmp)
Your problem is some Asic...
CW
16:18
C W
In reply to this message
I know right . Yes LDO gives me the 1.2v on its 5th pin for both the 1st and 88th chip. Booster circuit votages are normal too
J
16:45
Jasa
In reply to this message
What version is your hashboard S19... I check the info now and the voltage provide of regulator is 1.8volts and 0.8v
CW
16:51
C W
In reply to this message
It is s19 88 or s19 al did you get that info from Zeus mining ? Yea it says it should be around 1.8v and 0.8. But I’m reality it is around 1.2v ....
R
17:36
Rust Project
In reply to this message
But how to find him? On tester all 30 are ok ...
17:37
In reply to this message
17:38
What to understand from this? In normal mode all ok, but in advance mode 1 asic?! Tnx!
2022-September-16
R
04:01
Radu/nERD
In reply to this message
On chain 0 third temp sensor detects 184°. I think...maybe is not the sensor, try to replace the asic near the third temp sensor.
R
07:27
Radu/nERD
In reply to this message
I just have one. Normal test ok but advanced only 1 asic found and no temp sensor found, what to search for?
J
11:19
Jasa
In reply to this message
R
11:19
Rust Project
@Raulitiu Semnalele sunt OK? ma refer la cele de dupa chipul 1
CW
13:06
C W
In reply to this message
Yea thank you for sharing the material 👍 I know it says 1.8 volts but if you were to measure the voltage levels of ci, ro, and RST I am sure the levels should be close to 1.2v .... I don’t know why😓
A
13:16
ARC tester
In reply to this message
1.8 or 1.2 are logical levels, in most miners it is 1.8, but in C19 it is 1.2
CW
13:24
C W
In reply to this message
Thank you arc, did you mean s19?
A
13:25
ARC tester
In reply to this message
yes)
CW
13:52
C W
In reply to this message
Ok got it thank you 👍
2022-September-18
JT
20:23
Jeannot Tremblay
Hello. Hashboard BHB42631
S19j pro 104th

I have all my signals. But antminer see only 124 chips.

I changed 123,124,125,126 and same things

After I checked all chips and I have found two chips with ( B1 1.2v )

I've changed 109,110,111,112 and I have always ( B1 1.2v)

LDO : Ok
Resistance : Ok
Condensateur : Ok
2022-September-19
WK
07:44
Weerapat Klakasikorn
Video file
not-archived
01:14, 10.3 MB
F
13:10
Felipe
Hi guys I’m trying to fix s19j pro 96th
13:11
13:14
NA
13:20
Nestor Acosta
change the EEPROM, it is possible it is damaged, or some problem of cold welding
F
13:23
Felipe
would you have the Bhb42601 dump
13:23
Here i just saw 2631
NA
13:24
Nestor Acosta
In reply to this message
No
F
13:25
Felipe
NA
13:27
Nestor Acosta
In reply to this message
F
13:28
Felipe
Here bhb422631 is same like bhb42601?
13:29
NA
13:30
Nestor Acosta
In reply to this message
no but it works fine
F
13:31
Felipe
Great I will try
13:34
13:34
13:34
13:39
I will try others 3 options
13:47
Number 2 working thanks guys
13:48
Now show 124 of 126 chips i will open to try repair
R
17:38
Richard
Does anyone know why a S19J Pro board that is showing 0 Asic would be draining voltage? I have it hooked up to my power supply and when I run the ARC tester I get 0 Asic and my voltage begins to slowly drop?
R
17:40
Raz
In reply to this message
Hey Richard,
An ASIC showing 0 chips in the tester doesn't means that it's not working. It seems like a short somewhere. Could be a chip, could be something Else
17:41
You got Voltage going down and Current going up?
R
17:45
Richard
My voltage is dropping but current stays constant.
R
17:48
Raz
Do regular diagnosis method
17:48
Look if boost circuit got juice

Look RI signal from last chip to first
Check CLK
A
17:51
Austin CHR ~2210 Mining
Is it the aluminum back version?

If not does the voltage drain when not testing?

We can try to locate the short by injecting voltage before and after the mos, boost, etc.
R
18:11
Richard
It is not an aluminum backed board oddly enough
18:11
the voltage does not drain when not testing. I will try injecting voltage before and after those components to try to find the issue. Thanks Austin
JD
23:08
Joe D.S. JTS
Any update to support BHB42631 hashboard?
2022-September-20
V
11:28
Vilk
I need help machine is less then2 weeks old barely used because i been stuck in a bootloop
11:34
It worked fine for a week i was fixing many miners then it just randomly logged out. My wifi connection is good . Was able to go to reset the connection once and now it just flash start system and if hold ted button it just does failed to connect... Configuring access point
11:35
Video file
not-archived
01:08, 43.7 MB
A
12:34
ARC tester
In reply to this message
good afternoon! I'll send you a private message now
CN
21:36
Containfo Net
hello I am getting this error in the pic that can be done with asic repair
21:40
2022-September-21
R
00:45
Rust Project
I change pic when i get this error
A
01:04
ARC tester
In reply to this message
Hello! I will ask you personal
R
18:08
Richard
It looks like my ARC is stuck in a boot loop. Might you know how to remedy the issue?
18:08
Video file
not-archived
00:33, 4.5 MB
2022-September-22
CN
00:37
Containfo Net
In reply to this message
Ok
00:38
In reply to this message
I changed the eeprom memory and the problem was solved ..thanks ..
A
00:43
ARC tester
In reply to this message
have you changed the EEPROM on the hash board?
CN
00:44
Containfo Net
Yes ..
R
12:29
Richard
Might I be able to get some help troubleshooting my ARC tester? Its stuck in a boot loop and wont connect to the access point
2022-September-24
A
10:43
ARC tester
In reply to this message
Please replace this fuse. 0402 1a
2022-September-25
2022-September-26
TC
03:36
Thaha C V
hell good day
03:37
I need support how to updat ARC Asic tester .L7 Model not in my Tester
03:37
Also while updating showing error
A
03:40
ARC tester
In reply to this message
Hello! Serial number of your arc please
TC
03:59
Thaha C V
03:59
04:00
N10001214
A
04:13
ARC tester
What is version of software?
You have L7model in your tester.
Show me full screen of models list from web interface. You need know that you can scroll models list.
TC
04:20
Thaha C V
when i try to download the latest update hi give my error
A
04:21
ARC tester
In reply to this message
You have problem with internet connection or wi fi. Try another network or wi-fi router
TC
04:22
Thaha C V
this is the error
04:22
ead time
04:22
whats is mean
A
04:23
ARC tester
Show please
TC
04:24
Thaha C V
Thaha C V invited abdalrahman
A
04:49
ARC tester
In reply to this message
Problem with internet connection. Try another network, another wi-fi
TC
04:50
Thaha C V
ok i will try and see
A
23:46
ARC tester
In reply to this message
23:49
In reply to this message
hi! very strange, share the dump, we will study it. does the board work fine in the miner?
2022-September-27
NA
00:41
Nestor Acosta
hi, good day, dump for T15 please? someone?
MA
05:23
Meshal Adel
05:23
What is the use of the lighting and R ?
R
05:58
Rust Project
Lightning - advanced mode, test every chip individual, and R, reset to normal mode
A
06:07
ARC tester
In reply to this message
Not really. R switches to normal mode, but even in this mode, in each iteration, the hash board is reset with a reset signal. Without this option, the reset occurs once after the start of the test.
06:09
In reply to this message
An advanced mode is a mode in which an address is distributed to each chip and the polling takes place automatically. In normal mode, the survey is broadcast.
LN
06:10
Lawrence N
06:10
Hello
06:10
Temperature sensor flashing red/ green
06:10
What that supposed to mean?
R
06:10
Rust Project
an erronate temperature
06:10
out of range
06:11
something line -10 or 120 ...
06:11
like
LN
06:13
Lawrence N
Or not working properly? Or it will still work?

Jump to Page: