F
12:47
Felipe
I cannot start test , because when test is on show that msg
Normally when test is on and we plug some board , test show me s9 or s19 … and now I plug nothing happens ,
Normally when test is on and we plug some board , test show me s9 or s19 … and now I plug nothing happens ,
12:47
I have other friend here with same problem
12:48
I have 3 testers for you guys and just on doing like I show you
A
12:48
ARC tester
In reply to this message
Whats the serial number of the tester? You can find it on the back of it
F
12:48
Felipe

12:49
If you wanna can I send to you remote access just msg on pvt
A
12:50
ARC tester
Remote access to your pc wont give me anything useful
12:50
Have you tried different 18pin cables?
F
12:51
Felipe
Yes like I told you
I don’t need plug nothing to take that eprom error in red
I don’t need plug nothing to take that eprom error in red
A
12:52
ARC tester
In reply to this message
Wait a minute, you've got that error even without the board connected to the tester?
F
12:53
Felipe
Yes
12:53
If I try to plug some board still same like before
12:55
When we plug nothing hap
A
12:56
ARC tester
In reply to this message
ERROR PIC control [English].pdf
not-archived
39.2 MB
Perform the measurements as described in this file and send them to us
F
12:56
Felipe
Ok I will ask thanks
13:01
Video file
not-archived
01:52, 9.8 MB
C
13:38
Crypton2020🇧🇷🇦🇷🇵🇾
have to exchange epron
13:40
error she can't detect your problem in the data output don't get read the eprom error there some cup of the test output
13:42

NN
13:44
Nathan Nathan
Hi do you have a solution when there is 0 chips found but all signals are good?
CM
B
17:33
Bigzoe
In reply to this message
Trace your RO/RX and check where the voltage dropped and also check 0v8 and 1v8 but the problem is most likely broken RO/RX it’s 1.8v running from the last chip to the first chip
17:36
if you have 0v on RO/RX on the last chip Check the chip and if the chip is good then proceed to your boost chip
NN
17:39
Nathan Nathan
Rx is 1.8v to all chips
MA
18:02
Meshal Adel
Hello, anybody know what the voltage should I set for the T17+?
CW
18:03
C W
I have a question guys, does anyone know how to solve temperature for s19 pro?? Thanks!
MA
CW
18:08
C W
In reply to this message
Well it says in the miner log. “Temperature exceeds max temp, kill all hashboard” is it because the temp sensors are broken? All fans are good though
MA
18:10
Meshal Adel
Well, usually if the sensor are not working it would give an PIC error in the log … if it does not appears in the log then the sensor are ok and the temperature is high of the room if you are using air cooling
CW
18:13
C W
In reply to this message
Thank you! It does that “fail to read pic temp for chain 1” and “pic read iic failed ” we can conclude that this is a sensor problem right ?
MA
18:16
Meshal Adel
Yes … then let me give the common problems
CW
18:16
C W
In reply to this message
Does s19 pro uses the same temp sensor as s17+ (t451) ? Is it also on the back of the board ?
MA
18:18
Meshal Adel
No, sensor is TMP75
CW
18:20
C W
In reply to this message
Wow, they have actually changed it. Thank you very much Meshal really appreciate it !👍👍
MA
18:21
Meshal Adel
Usually if you have a PIC problem then the cause one of the following:
1. tmp sensor failure, and can be solved by replace the TMP sensor (most common the inlet sensor)
2. Resistors and capacitor connected to TMP sensor (missed or damaged). This is solved by replacing them
3. Track between the sensors, tracks might be rusted or damaged. Can use multimeter to check the connection between them pin1 in TMP1 should be connected to pin1 in TMP2 then pin1 in TMP3 and filing Pin1 in TMP4. Do the same Pin2, Pin4 and Pin8
1. tmp sensor failure, and can be solved by replace the TMP sensor (most common the inlet sensor)
2. Resistors and capacitor connected to TMP sensor (missed or damaged). This is solved by replacing them
3. Track between the sensors, tracks might be rusted or damaged. Can use multimeter to check the connection between them pin1 in TMP1 should be connected to pin1 in TMP2 then pin1 in TMP3 and filing Pin1 in TMP4. Do the same Pin2, Pin4 and Pin8
CW
18:24
C W
In reply to this message
Amazing !! Thank you so much !! I wish your message could be pinned so that more people could see it !! Fantastic !!
MA
18:26
Meshal Adel
Your more than welcome I happy that these was useful
18:26

18:27
Resistors and capacitors connected to the sensors … each with resistor and capacitor has a number and a value
18:27
Good luck
CW
MA
18:28
Meshal Adel

18:28
This is more clear
CW
18:30
C W
In reply to this message
Thank you so much dude !!! Really appreciate it, you have been such a tremendous help !!
MA
18:32
Meshal Adel
Your more than welcome
18:33
I need any further inquires I will be more than happy to answer
CW
M
18:36
Mh
hi which line hold temp signal in 17+ antminer
CW
18:43
C W
In reply to this message
Do you mean the pin of the chip or the physical location of the temp sensor on the board ?
M
18:45
Mh
no the line like Ro Ci
which line ?
which line ?
CW
18:46
C W
In reply to this message
I have a further question, so I found the temp sensor on s19 pro, but on all s19 pro boards 4 of the resistors that attached to U8 temp sensor 2 are 100 ohms and other 2 are 4.7k ohms 😓
18:48
In reply to this message
Oh I think it is pin 21 and 22. I don’t think there is a test point for that.
M
18:53
Mh
these lines go to sensor but temperature must go to pic
which line hold signal to pic
which line hold signal to pic
18:55

18:55
it must be one of these
CW
M
CW
19:00
C W
In reply to this message
I am not sure though , hopefully someone else could give you a more definite answer sorry😓
M
MA
19:22
Meshal Adel
In reply to this message
I do not know what you mean 100 ohm … if we take U8 for example … pin1 is connected to R215(4.7 Kohm) and pin2 connected to R214(4.7 Kohm)
19:22
Pin5, 6 and 7 connected to 1K ohm
19:22
And Pin8 to capacitor 100nF
CW
MA
EL
22:14
Eric Liu

22:14

22:14
This is 19 board.
22:15
Did I do something wrong?
CW
EL
23:25
Eric Liu
Yes, now it works
23:25
Thanks
23:25
I forgot
2022-June-9
Bigzoe removed Bigzoe
AM
08:15
Aleksandr Muranov

Why I need flash eprom every time I connect board?
A
08:54
ARC tester
In reply to this message
Hi, whats the serial number of your unit, whats the fw version?
JM
11:33
Jan Makie

What is the problem I don’t know
11:33

11:43
???
AM
A
JM
11:49
Jan Makie
Already I update version 1.341
AM
11:54
Aleksandr Muranov

11:54
how can i update?
A
11:58
ARC tester
In reply to this message
Reboot the tester, then refresh the page with cache clearing (Cntrl + F5)
JM
11:58
Jan Makie

12:00
not working
A
12:03
ARC tester
In reply to this message
What is not working? I'm telling Aleksandr to update to fix his issue
JM
12:22
Jan Makie
No
12:24
About for that one information
AM
15:35
Aleksandr Muranov

Whats wrong? its first time i try to repair Wats
HS
15:37
Hayden Sheehan
Please can you update the L3+. Regardless of the data cable I use, the tester picks up no chips, even though the 6 boards I tried it on are working perfectly.
JM
15:53
Jan Makie
Please update your taster 1.341 version
AB
17:03
Aurélien Bucher
Hello i use the tool, but can we get some more info on which chip to change ? If i have number 3 in red for exemple on a T17 ?
A
19:38
Arthur
Hello does anyone here knows a good source for learning a teaching repairing Bitmain s19 miners. Compared to the s17 repair information for s19 is rare
@
19:53
@Fiobello
In reply to this message
Hello ! If you have asic 3 in red, it means that the programmer is telling you that the signal is even there. Logically you would have to change the asic 4, of course, you would have to check signals before determining a change of asic .. visually check if it has the resistance, or if it does not have any trace of tin stuck by the asic 3 or 4.
2022-June-10
AB
CW
13:31
C W
Hello guys I have a question about m20s we. I don’t have TXD voltage at U6 after multiple chip swaps. I have RST, CLK, and RXD all the way through U1->U105. Fixture still says RST fail and check power😓
13:32
Does anyone know the solution to this problem ?? Thank you !!
A
14:28
Amnart - Thailand
Check level convert also
14:29
Must have wave form at 1.8v pin and 3.3v pin
AT
14:31
Aisupat Thaweekarn
👍 professor
CW
KT
14:52
Kasidit Tirawatanakan

14:52
How to fix this problem? Voltage is 401.27 V
14:53
Please
SV
14:54
Serega Vishnya
30 chip RI/RO? Sorry, from Russia
14:54
Look RI 30-1
Saul invited Jacob Ewart
KT
14:56
Kasidit Tirawatanakan

14:57
0 V of first input check point
SV
14:57
Serega Vishnya
Ooou. Stop. What is mainer?
KT
14:58
Kasidit Tirawatanakan
T17
SV
14:58
Serega Vishnya
Look RI in test point
14:59
Between 30 and 29 chip
15:01
- on radiator domain, + RI 30-29
KT
15:08
Kasidit Tirawatanakan
I change all mosfet and it’s work
15:08

15:09
But voltage still high
15:09
I will try to run with miner and see the result
A
KT
15:33
Kasidit Tirawatanakan

15:34
voltage 0, miner cannot run
15:34
anybody help, please
SV
15:35
Serega Vishnya
Replace Pic, eeprom and Transceivers
CW
15:47
C W
In reply to this message
Thank you very much Amnart ! But if I have RST and CLK coming out of U6 then it would mean that my voltage circuit is correct right ? It is just the TXD that is abnormal.
15:48
In reply to this message
Yea I would definitely check the pic as too 401V for a T17 board is wayyy too high
CW
18:32
C W
Guys, What does x19jx mean ??
18:34

CW
19:26
C W
Is it some sort of error?
2022-June-11
A
01:08
ARC tester
In reply to this message
Bitmain is constantly changing the structure and method of encryption of EEPROM, you have come across a board with a type of EEPROM unknown to the tester, please save the dump and throw it here, we will add it to the tester and everything will work.
CW
CW
19:09
C W
In reply to this message
Sorry ARC, I have a follow up question, could you point me to a tutorial where I can find how to save and port out the dump file from the fixture ?? Thank you so much !!
2022-June-12
A
K
13:50
Kenme
Hello guys I’m new to this channel.
I have replaced this button because it wasn’t making proper contact.
Here is the link
Vamos a ahorrar juntos en AliExpress con cupones de nuevo usuario.
¡Toma € 0,96 en cupones!
https://a.aliexpress.com/_mMnLQmS
I have replaced this button because it wasn’t making proper contact.
Here is the link
Vamos a ahorrar juntos en AliExpress con cupones de nuevo usuario.
¡Toma € 0,96 en cupones!
https://a.aliexpress.com/_mMnLQmS
13:52
Video file
not-archived
00:03, 1.2 MB
13:54
I also want to ask something
I have a bunch of T17e and S17 (more than 10 boards) that won’t mine because the original bitmain software shows “0” asic found, whereas the ARC Tester shows 78 asic.
So it quite difficulties repair …
Is there something I can do ?
I have a bunch of T17e and S17 (more than 10 boards) that won’t mine because the original bitmain software shows “0” asic found, whereas the ARC Tester shows 78 asic.
So it quite difficulties repair …
Is there something I can do ?
M
13:56
Mathew
Do you using original psu ?
K
13:59
Kenme
On the tester or on the asic ?
M
13:59
Mathew
Tester
K
13:59
Kenme
I bought the power supply at Amazon
13:59
At18V
14:00
On the T17e
M
14:00
Mathew
Try 21, becasue miner start with this voltage
K
14:01
Kenme
Ok
Thank do the advice !
Thank do the advice !
K
14:16
Kenme

14:16

14:17
Video file
not-archived
00:40, 12.5 MB
14:17
I just checked it and it does the test with 19V
14:17
Any help will be very much appreciated 😄
A
19:02
Arthur
In reply to this message
Has to be psu or control board or flatcable connection . Switch them to see if there is any difference
K
19:16
Kenme
Thanks
Will try that tomorrow!
Will try that tomorrow!
2022-June-13
CW
11:56
C W
In reply to this message
@ARC the serial number of my tester is 10000865 could you please walk me through the steps please ? Thank you !!
2022-June-14
M
04:24
Mh

04:25
s17+ how can i detect high temp chip
04:28

A
05:09
ARC tester
In reply to this message
Hi, just connect the board to the tester, go to the "EEPROm edit" tab in web interface and press "Download EEPROM file" in the upper right corner of the window
MA
07:10
Meshal Adel
Hello, does the ARC support S19+ 99T ?
CW
C
12:02
Crypton2020🇧🇷🇦🇷🇵🇾
could someone give me a dump m31s of 105 chip
CW
12:16
C W
dump_S19.bin
not-archived
256 B
12:17
In reply to this message
Is this good? I uploaded the dump file, I tried to write the epprom for this board with tester as s19, but I might have done something wrong there ...
A
CW
2022-June-15
M
04:04
Mathew
Does anyone repair the APW12 PSU ?
A
09:59
Alejandro
Hello good morning !! Could anyone tell me why my Asic repair used to give me bad chips and now even good hashboards give me 0 asics?
A
10:04
ARC tester
In reply to this message
Hi, whats the serial number of your unit? What fw version it is running right now?
A
A
10:08
ARC tester
In reply to this message
Do you have a problem with a particular board model or is it all the boards that you receive 0 asics?
EB
10:43
Edward Brock
Do i need to power the hash board, with this unit to detect bad or good chips? Specifically the Whatsminer Unit
M
EB
11:11
Edward Brock
In reply to this message
ok can i use the PSU form the unit itself? or do i need to buy something more? links preferred so i can send to purchasing, thank you, sorry i am a noob at this type of repairs
JM
11:13
Jan Makie

11:13
How to find the problem
11:14
please help me
A
CW
13:03
C W
Hello Arc ! I was wondering if there were any updates in regards to the dump file I uploaded yesterday for my s19 board ? Thank you !
A
13:06
Alejandro
In reply to this message
With all of them at this time, both from L3 T17 S19 and the S9 before, if it detected me, but it has been about 3 days since they all started to mark 0asic, even when the chips work.
A
13:07
ARC tester
In reply to this message
We will reach out to you as soon as we have any info on it
13:08
ERROR PIC control [English].pdf
not-archived
39.2 MB
13:08
In reply to this message
Got it
Please perform the measurements as described in the attached file and let us know about the results
Please perform the measurements as described in the attached file and let us know about the results
M
13:10
Mathew
In reply to this message
1 of 65 Asics is Bad, short 1,8 and RO signal and find bad asic. One asic chip gives -1 chip error, so for example when you short chip 30 and tester show 29 and when you short chip 29 and found 29chips, 30chip IS bad
A
CW
C
15:15
Corey

15:16
Tester is stuck on EEPROM no matter what board I plug in. I have rebooted it several times also. How do I reset it or get it back to normal?
F
16:26
Felipe
I got some problm
2022-June-16
A
04:57
ARC tester
In reply to this message
Hi, press the model selector knob and turn it while pushed in